Global radiation transmitter
Sensors
162100 | for global radiation |
163100 | for radiation balance |
Sensor for global radiation
Measuring principle:
Determination by means of thermocouples of the radiation-borne excess temperature of a black receiving surface
Technical parameters:
Measuring range | 0 ... 1400 Wm-² |
Sensitivity | ca. 10 µV/Wm-² |
Error of measurement | < 2.5% |
Time constant | < 18s for 95% of end value |
Spectral region | 0,3 ... 2,8 μm |
Temperature range for operation | -40 °C ... +80 °C |
Sensor for radiation balance
Measuring principle:
Measurement of difference between incoming radiation and reflected radiation
Technical parameters:
Measuring range | 300 ... +1000 Wm-² |
Sensitivity | ca. 10 µV/Wm-² |
Error of measurement | 0,3 ... 60 µm |
Time constant | < 20s for 90% of end value |
Temperature range for operation | -40 °C ... +80 °C |