Menu
Products

Soilmoisture Lab Setups for Pressure Plate Extractors

Soilmoisture Lab Setups for Pressure Plate Extractors

Item no.: 5080937 (Lab Setup for 5 bar) Art-Nr.: 5080935 (Lab Setup for 15 bar) Item no.: 5080933 (Lab Setup for 5 bar & 15 bar)

Advantages at a glance

  • relatively simple handling
  • reliable method
  • undisturbed soil extraction

Please send me more information about Soilmoisture Lab Setups for Pressure Plate Extractors

Soilmoisture Lab Setups for Pressure Plate Extractors

The equipment is suitable for the determination of pF curves in the range of pF 2.0-4.2 (0.1-15 bars of soil moisture tension). Furthermore, the sets are suitable for the calibration of soil moisture blocks or other soil moisture measurement equipment. Several ceramic plates with soil samples can be placed in the extractor at the same time. The pressure control panel is standard equipped with two manometers 0-2 MPa and 0-0.4 MPa (and 0-20 bars and 0-4 bars). The supplied compressor (220V / 50 Hz) is specifically designed for this purpose: maximum pressure 2.0 MPa (20 bars), built in safety precautions, completely guarded and quiet.

If the properties of the moist soil sample are known, the following values may be determined:

  • The pore volume of the soil
  • The pore size distribution of the soil
  • The capillary rise capacity
  • The air and moisture contents of the soil with a given ground water level
  • Determination of the field capacity and available soil moisture
  • Water tension with respect to the germination time of seeds

Principle

Moisture is removed from the soil samples by raising the air pressure in an extractor. A porous ceramic plate serves as a hydraulic link for water to move from the soil to the exterior of the extractor. The high pressure air will not flow through the pores in the plate because these are filled with water. The smaller the pore size, the higher the pressure can be before air will pass through. During the test run at any set pressure in the extractor, soil moisture will flow around each of the soil particles and out through the ceramic plate and outflow tube. Equilibrium is reached when water flow from the outflow tube ceases. At equilibrium, there is an exact relationship between the air pressure in the extractor and the water tension in the samples (and hence the moisture content). Accuracy of equilibrium values will not be above that of the regulation of air supply. Therefore, the pressure control panel has independent double regulators.

Advantages

Compared to other methods, such as compaction, centrifugation, molecular absorption etc, the advantages are as follows:

  • Relatively simple method.
  • Reliable way of removing soil moisture from soil samples under controlled conditions without disturbing the soil structure.
  • The method may be used on prepared samples or undisturbed samples. The soil structure is not disturbed. The characteristic pF curves may be developed for each soil type. These curves relate the moisture tension at which the moisture is held in soil to its moisture content. Studies of soil moisture movement and of quantity and availability of soil moisture have shown this relationship to be important for plant growth.

Drucktopf-Set für 5 bar enthält:

  • 5-bar-Drucktopf 1600F1 (Art.-Nr. 5080417)
  • Druckregel-Panel für 5 bar (Art.-Nr.: 5080372)
  • 4 x Keramikplatte 1 bar high flow (Art.-Nr.: 5080418)
  • 4 x Keramikplatte 3 bar Standard (Art.-Nr.: 5080460)
  • 4 x Keramikplatte 5 bar Standard (Art.-Nr.: 5080461)
  • Verbindungsschlauch 5 bar 0776L60, 1,5 m (Art.-Nr. 5080373)
  • 4 x Sets Bodenprobenringe, je 12 Stück, AD 6 cm, Höhe 1 cm (Art.-Nr.: 5080536)
  • Kompressor 20 bar, inkl. Verbindungsschlauch 0079G1 (Art.-Nr.: 5080112)

Drucktopf-Set für 15 bar enthält:

  • 15-bar-Drucktopf 1500F2 (Art.-Nr. 5080526)
  • Druckregel-Panel für 15 bar (Art.-Nr.: 5080352)
  • 4 x Keramikplatte 1 bar high flow (Art.-Nr.: 5080418)
  • 4 x Keramikplatte 3 bar Standard (Art.-Nr.: 5080460)
  • 4 x Keramikplatte 5 bar Standard (Art.-Nr.: 5080461)
  • 4 x Keramikplatte 15 bar Standard (Art.-Nr.: 5080350)
  • Hydraulik-Scharnier für 15-bar-Drucktopf (Art.-Nr.: 5080354)
  • Verbindungsschlauch 15 bar 0775L60, 1,5 m (Art.-Nr. 5080353)
  • 4 x Sets Bodenprobenringe (je 12 Stück), AD 6 cm, Höhe 1 cm (Art.-Nr.: 5080536)
  • Kompressor 20 bar, inkl. Verbindungsschlauch 0079G1 (Art.-Nr.: 5080112)

Drucktopf-Set für 5 bar und 15 bar enthält:

  • 5-bar-Drucktopf 1600F1 (Art.-Nr. 5080417)
  • 15-bar-Drucktopf 1500F2 (Art.-Nr. 5080526)
  • Druckregel-Panel für 5 und 15 bar (Art.-Nr.: 5080111)
  • 4 x Keramikplatte 1 bar high flow (Art.-Nr.: 5080418)
  • 4 x Keramikplatte 3 bar Standard (Art.-Nr.: 5080460)
  • 4 x Keramikplatte 5 bar Standard (Art.-Nr.: 5080461)
  • 4 x Keramikplatte 15 bar Standard (Art.-Nr.: 5080350)
  • Hydraulik-Scharnier für 15-bar-Drucktopf (Art.-Nr.: 5080354)
  • Verbindungsschlauch 0776L60, 1,5 m (Art.-Nr. 5080373)
  • Verbindungsschlauch 15 bar 0775L60, 1,5 m (Art.-Nr. 5080353)
  • 4 x Sets Bodenprobenringe (je 12 Stück), AD 6 cm, Höhe 1 cm (Art.-Nr.: 5080536)
  • Kompressor 20 bar, inkl. Verbindungsschlauch 0079G1 (Art.-Nr.: 5080112)

Alle Einzelteile sowie anderes Zubehör können Sie auch einzeln bei uns bestellen. Kontaktieren Sie uns gerne.