UGT TerraFlux gas measuring chamber
UGT TerraFlux gas measuring chamber
The TerraFlux is a portable, automatic gas measurement hood that we have developed specifically for the precise measurement of gas fluxes from plants and soil. It is available in diameters of 300 or 500 mm and in either a transparent or opaque version. Furthermore the height is extendable with intermediate stackable segments.
Advantages of soil flux measurement with the TerraFlux
- Transparent or opaque, gas-tight hood with minimal self-shading: Enables precise measurement of the Net Ecosystem Exchange (NEE) of soils or measurement of soil respiration (SR)
- Closed dynamic system (non-steady-state through-flow): The air measured in the gas analyzer is recirculated, preventing negative pressure. Ideal for determining gas accumulations or decreases over extended periods.
Compatibility & Installation
- Easy connection to gas analyzers and/or UGT multiplexers
- Control via a Picarro gas analyzer or via a PC running Windows, Linux, or macOS (communication and data exchange via Modbus)
- A smart version with the option to connect additional sensors is available upon request
- Easy installation with a drive-in blade and four soil screws
Applications
- Research on carbon balance, greenhouse gases, climate change, etc.
- Agricultural emission studies
- Greenhouse gas monitoring
- Landfill gas measurement
- Soil restoration and remediation
- Carbon management and emissions trading
|
Parameters |
Specifications |
|
Overall dimensions when closed with the drive-in blade (L x W x H) |
845 x 660 x 605 mm |
|
Drive-in blade (L x W x H) |
759 x 588 x 103 mm |
|
TerraFlux, closed, without drive-in blade (L x W x H) |
845 x 660 x 502 mm |
|
TerraFlux, open, without drive-in blade (L x W x H) |
1250 x 660 x 922 mm |
|
Chamber height |
485 mm, extendable with intermediate segments |
|
Chamber diameter |
Ø 500 mm |
|
Chamber / drive-in blade weight |
17 / 9 kg |
|
Chamber volume (above soil surface) |
85 l |
|
Soil coverage Area |
0.2 m² |
|
Material Chamber |
PMMA |
|
Material Frame |
powder-coated stainless steel (white) / aluminum / PMMA |
|
Material Gas line |
PE or FEP; other materials available on request |
|
Air circulation |
available, Non-Steady-State-Through-Flow |
|
Hood closing speed |
40 s |
|
Connection options |
connection to gas analyzers and/or UGT multiplexers |
|
Hose connection options |
max. Ø 12 mm |
|
Sensor connection options |
barometric pressure sensor and temperature sensor, additional sensors available upon request |
|
Cable length between chamber and analyzer |
10 m; other cable lengths available on request |
|
Soil mounting |
drive-in blade and four soil screws |
|
Power supply |
24 V, 4 A |
|
Operating temperature |
-20 … 50°C |
|
Humidity |
0 … 100% |